Flashover is a rapid transition in a compartment fire, such as a fire in a room, from localized burning to widespread fire involvement. It can expose occupants and firefighters to extreme heat and leave little time to escape. Understanding how it develops helps facility leaders plan for prevention and evacuation without asking workers to predict fire behaviour.
As a fire grows inside an enclosed space, hot gases and smoke accumulate near the ceiling. Heat from the fire and hot gas layer is transferred to furnishings and other exposed combustibles. When enough exposed material reaches ignition conditions, fire can spread rapidly throughout the compartment, with multiple surfaces igniting at approximately the same time. Not every material ignites at exactly the same instant, and not every fire reaches flashover. The National Institute of Standards and Technology (NIST) describes flashover as a transition in fire development, not a temperature that a worker can safely wait to observe.
Fire growth depends on the fuel, the space, the heat produced and the air available. A fire can become ventilation-limited when oxygen is depleted. Opening a door or window can then introduce air and cause rapid fire growth, potentially leading to flashover. Do not open doors or windows to ventilate a burning building as an improvised fire-control measure. Firefighting ventilation and suppression are tasks for trained, authorized responders using their incident command procedures.
Firefighters are trained to assess changing conditions as a whole. The U.S. National Fire Academy identifies intense heat, a buildup of smoke, flames rolling across the ceiling and previously unburned items beginning to smoke among signs associated with possible flashover. These signs may be difficult to see or interpret. NIOSH recommends considering indicators together rather than focusing on just one. No single sign reliably predicts when flashover will occur, and a change from yellow to white flame is not a dependable warning rule.
NIST notes that warning signs can be missed, particularly in heavy smoke. Workers who discover a fire should leave the fire area and raise the alarm. When an alarm sounds, follow the facility's fire safety plan and the directions of emergency services; do not delay to look for flashover signs. Smoke, heat and fire can be dangerous even when flashover has not occurred.
Follow the facility's fire safety plan and the direction of emergency services. The Canadian Centre for Occupational Health and Safety (CCOHS) recommends procedures that cover sounding the alarm, contacting the fire department and evacuating occupants.
If smoke, heat or flames block your exit, use another safe exit if one is available. If you cannot get out, close a door between you and the fire where possible, call the local emergency number, tell responders your location and follow their instructions. The U.S. Fire Administration also advises signalling for help at a window if you are trapped.
Portable extinguishers are for limited situations, not an alternative to evacuation. Under the site plan, a trained and authorized person may attempt to fight a small, contained fire only after others have been alerted and the fire department has been called, and only if the person knows what is burning, has the correct extinguisher and has a clear exit behind them. If the fire grows, smoke or heat makes conditions unsafe, or the person is unsure, leave immediately; ensure the alarm has been raised and the fire department called. See CCOHS guidance and OSHA's extinguisher risk-assessment guidance.
Flashover awareness is only one part of a fire safety program. A property-specific plan should address the materials, work processes, layout and occupants of the facility. CCOHS recommends reviewing the site, its fire hazards and protection systems when preparing a fire safety plan. Useful measures include:
Properly designed and maintained sprinklers can control a fire and may prevent flashover, but their performance depends on the system and the fire. In one NIST furnished residential-room experiment involving a burning dry Christmas tree, a single residential sprinkler prevented flashover and limited spread to other objects. That result is not a guarantee for every building or fire.
In Canada, the National Fire Code is a model code. It takes legal effect through adoption by a responsible regulatory authority and may be modified. The model fire code addresses fire prevention and protection in the ongoing operation of buildings and facilities, while the model building code addresses building design and construction. Check the adopted provincial or territorial requirements, local requirements and applicable occupational health and safety laws for the facility. Federal workplace requirements also apply to some industries and workplaces.
For example, in Ontario, Occupational Health and Safety Act section 25(2)(a) requires employers covered by the Act to provide a worker with information, instruction and supervision to protect the worker's health or safety. This is a general duty; the specific fire precautions and training needed depend on the workplace and other applicable rules.
In the United States, OSHA has different fire-safety rules for general industry, construction and other sectors; state-plan and local requirements may also apply. For general industry, 29 CFR 1910.38 applies when another OSHA standard in Part 1910 requires an emergency action plan. Among other elements, the plan must address reporting, evacuation and accounting for employees; the rule also addresses training designated employees to assist with evacuation. This is not a statement that every U.S. workplace must have a plan under that section.
NFPA and other consensus documents can provide useful guidance, but they do not automatically become OSHA regulations simply by being published. Specific standards or provisions may become enforceable when adopted or incorporated into applicable law. See OSHA's fire safety standards overview and its explanation of incorporated consensus standards.
This overview is not a site emergency plan. Have a qualified fire-protection professional and the relevant authority review the requirements and arrangements for your facility. For more information about Total Group, visit totalgroup.ca.